JCGP Gauge Pressure Transmitter
JCGP Gauge Pressure Transmitter is a digital gauge pressure transmitter with 4-20ma and hart.
- Introduction
- Parameters
- Model
- How to Order
- Video
JCGP Gauge Pressure Transmitter
JCGP type (smart) pressure transmitter has high overpressure strength and good stability.
Input span: 0~0.25kPa, 0~10Mpa, 0~40Mpa.
Service medium: liquid, gas and steam
Overpressure limit:
Span is the impose below 6Mpa: 0 (absolute pressure) ~14MPA
Span is the impose of 20Mpa: 0 (absolute pressure) ~32MPA
Span is the impose of 40Mpa: 0 (absolute pressure) ~52MPA
Flange can afford 60MPa pressure.
Feature
● High accuracy
● No mechanical and movable parts, little repair work
● Span and zero continuous and adjustable from outside
● Good stability
● Positive shift amount to 500%; negative shift 600%
● Two-wire system 4~20mA DC
● Damping adjustable, overpressure protection
● Solid components, patch-type printed circuit board
● Explosion-proof structure, all-day use
● Unified structure, strong interchangeability of parts
● Miniaturization(total height 166mm)
● Diaphragm materials of contacting mediums option (316L, TAN, HAS-C, MONEL, etc.)
● smart HART protocol
Techncal Parameter
● Service: liquid, gas and steam
● Measuring range : 0~0.06 kPa to 0~40Mpa
● Output signal : 4~20mA DC (four-wire 220V AC power supply, 0~10mA DC output for special)
● Power supply : 12~45V DC, generally 24V DC
● Features of loading: relation equation of loading impedance RL and power voltage
Vs: RL <= 50(Vs-12)
● Indicator : pointer-type linearity indication 0~100% scale mark or LCD indicator, LED indicator.
● Explosion proof : a. explosion isolation d II CT6
b. intrinsically safe ia II CT6
● Positive and negative shifts : after positive and negative shifts of zero absolute values of upper-and-lower-limit values of span and measuring range not exceed 100% of upper limit of measuring range.( smart type : turn down ratio 20:1, 40:1)
Maximum positive shift is 500% of minimum adjusting span; maximum negative shift is 600% of minimum adjusting span.
● Temperature range: amplifier operation temperature range: -29 ~ +93C
(LT type: -25 ~ +70C); measuring component of fill silicone oil: -40 ~ +104C
flange type transmitter fill hi-temperature silicone oil: -20 ~ +315C normal silicone oil: -40 ~ +149C
● Static pressure : 4, 10, 25, 32Mpa
● Humidity : relative humidity 0~100%
● Volume absorption : < 0.16cm3
● Damping (phase step response) : For silicone oil, generally between 0.2s and1.67s, continuous and adjustable
(no shift, under standard operation conditions, fill silicone oil, 316 SS diaphragm)
● Accuracy class: +/-0.25%, +/-0.5% (smart type: +/-0.1%, +/-0.075%)
● Dead zone: no (<=0.1%)
● Stability : within 6 months not beyond absolute value of basic error of maximum span
● Vibration effect: on a random ax upward, at vibration frequency of 200 Hz, error +/-5%/g of upper limit of measuring range.
● Power effect : < 0.005%/V of output span
● Loading effect : no effect from loading at stable power
● Effect of installation position : at most 0.24kPa of zero error, no effect on span
Other
● Diaphragm: 316 SS, HC -276, Monel or Ta
● Exhaust/vent Valve: 316 SS, HC or Monel
● Flange and Connector: 316 SS, HC or Monel
● Contacting medium “O” ring: acrylotrile-butadiene rubber, fluorine rubber
● Fill liquid: silicone oil or inert oil
● Blot: 316 SS
● Electronic Body Material: low copper-aluminum alloy
● Ignition Voltage Connection Fit : flange NPT 1/4, center distance 54mm; connector NPT 1/2 or M20 ×1.5 male round-cone surface sealed, when carrying connector the center distance 50.8, 54, 57.2mm (NPT taper thread accords with GB/T12716-91)
● Signal line connecting hole : G 1/2″
● Weight : 4.2 kg (standard type)
Model Selection for JCGP Gauge Pressure Transmitter
Smart Differential /Gauge /Absolute Pressure Transmitter | ||
JC | ||
Type | DP | Differential Pressure Transmitter |
GP | Gauge Pressure Transmitter | |
AP | Absolute Pressure Transmitter | |
Pressure Range | 2 | 0 – 0.125 (0.015) Kpa … 0 – 1.5 Kpa (Type D/G) |
3 | 0 – 1.3 (0.075) Kpa … 0 – 7.5 Kpa (Type D/G) | |
4 | 0 – 6.2 (0.37) Kpa … 0 – 37 Kpa | |
5 | 0 – 30 (1.8) Kpa … 0 – 180 Kpa | |
6 | 0 – 117 (6.9) Kpa … 0 – 690 Kpa | |
7 | 0 – 350 (20) Kpa … 0 – 2000 Kpa | |
8 | 0 – 1.17 (0.068) Mpa … 0 – 6.8 Mpa | |
9 | 0 – 4.0 (0.25) Mpa … 0 – 25 Mpa | |
Diaphragm Material | N | Stainless Steel 316L |
B | Hastelloy B | |
C | Hastelloy C | |
P | Monel | |
T | Tantalum | |
0 | Other | |
Process Flanges, Drain/Vent
valve Material |
N | Stainless Steel 304 |
S | Stainless Steel 316L | |
Explosion-proof | N | Exd IICT 6 |
S | Intrinsically Safe Exib II CT5 | |
Mounting bracket material | N | Carbon Steel |
4 | Stainless Steel 304SS | |
Wetted o-ring Material | N | Buna-N |
V | Viton | |
P | PTFE | |
Fill Fluid | N | Silicone |
F | Fluorine | |
Process connection | N | 1/4″ – 18 NPT |
A | 1/2″ – 14 NPT( with Adapter) | |
Z | Other | |
Cable Entry | N | M20 Conduit Threads |
P | 1/2″ NPT( Female) | |
Z | Other | |
Maximum Pressure Limit | N | 4 MPa |
1 | 6.4 MPa | |
2 | 16 MPa | |
3 | 40 MPa | |
Optional | 2V | With 2 way valve manifold |
3V | With 3 way manifold | |
5V | With 5 way manifold |
How to order JCGP Gauge Pressure Transmitter
- Medium
- Range
- Working pressure
- Working temperature
- Process connection