JC090 Sanitary Electromagnetic Flowmeter

Sanitary Electromagnetic Flowmeter is used in sanitary industries, such as food, pharmaceutical, etc.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months

Sanitary Electromagnetic Flowmeter

Sanitary Electromagnetic Flowmeter is used in sanitary industries, such as food, pharmaceutical, etc., require timely high-temperature steam to sterilize and clean in processes, the remaining medium be not allowed to stay on the place where pipe connection to prevent the bacilli propagate, therefore a quick install meter with hoop produced in sanitary industries.

Sanitary-connection-electromagnetic-flowmeter

● Simple structures, firm, no movable parts, and long operation life

● No intercepting fluid parts, no pressure loss, and fluid clogging

● No mechanical inertia, quick response, and good stability apply in the automatic examination, adjustment, and control

● Measuring accuracy is not influenced by physical parameters such as style, temperature, viscosity, density, and pressure.

● Employ Teflon or rubber liner and different combinations of an electrode material such as Hastelloy C, Hastelloy B, 316L,

● Titanium and adapt to the need of different mediums.

● Supply many styles of flowmeters such as inline type and insertion type, etc.

● Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.

● Integral type flowmeters and remote type flowmeters.

● LCD backlight display with high clearness

Technical Parameter

Suitable Diameter DN10~DN80 (below DN25 non-standard, which should be customized)
Electrodes Materials 316L (stainless steel), Hastelloy C, Hastelloy B, Titanium, Tantalum
Suitable Fluid Liquid with a conductive ratio of more than 5 μs/cm
Measuring Range 0.1~10m/s (extendable to 15m/s)
Upper Limit of Span 0.5~10m/s. 1~5m/s recommended
Accuracy 0.3%, 0.5%,1.0%
Output Signals 4~20mADC, load<= 750ohm, 0~3kHz, 5V with source and changeable width. high terminal and effective frequency output, RS485 interface
Operation Pressure 1.0MPa, 1.6MPa, 4.0MPa, 16MPa (special)
Fluid Temperature -20C~80C, 80C~130C, 130C~180C Depending on Lining Material
Ambient Temperature Sensor -40C~80C. transducer -15C~50C
Ambient Humidity <= 85%RH (at 20C)
Cable Outlet Size M20(16) ×1.5, 1/2″ NPT
Power Supply 220VAC±10%, 50Hz±1Hz, 24VDC±10%
Power Consumption <=8W
Protection Ratings Integral type: IP65. remote type: sensor IP68, transducer IP65
Materials of Liner PTFE, soft rubber, hard rubber, PFA, etc
Process Connection Thread: NPT, BSP, G Tri-clamp connection
Earthing Materials 316L (stainless steel), HC, Ti, Ta, Cu
Housing Material Carbon steel, 304SS, 316SS

 

Range DN15 to DN 80
Liner PTFE or F46
Rated pressure 1.6Mpa, Special custom-made
Body Material Stainless Steel (304SS)

Model Selection

Code Nominal Diameter
(mm)
Flow Range
(m3/h)
JC-090-10
JC-090-15
JC-090-20
JC-090-25
JC-090-32
JC-090-40
JC-090-50
JC-090-65
JC-090-80
Dn10
DN15
DN20
DN25
DN32
DN40
DN50
DN65
0.085-2.8
0.19~6.36
0.34~11.3
0.53~17.66
0.87~28.94
1.36~45.22
2.12~70.65
3.58~119.40
5.43~180.86
Code Electrode Material
K1
K2
K3
K4
K5
K6
K7
SS 316L
Hastelloy B
Hastelloy C
Titanium
Tantalum
Pt/Iridium Alloy
Stainless Steel Painting Tungsten Carbide
Code   Material of liner
C1
C2
C3
C4
C5
C6
C7
PTFE (F4 or Teflon)
Fluorinated Ethylene Propylene (FEP)
Fs
PO (Soft Rubber)
Polyurethane Rubber (PUR)
Hard Rubber
PFA
Code Function

E1
E2
E3
F1
F2

F3
F4
T1
T2
T3
P1
P2
P3
P4
P0
D1
D2
D3
J1
J2
J3
W1
W2
W3

Class 0.3%
Class 0.5%
Class 1.0%
4~20mADC, load ≤750Ω
0~3kHz, 5V active, changeable pulse, high-terminal and effective frequency output
RS 485 interface (Modbus)
HART
Normal Temperature
High Temperature
Ultra Temperature
1.0MPa
1.6MPa
4.0MPa
16MPa
Special Pressure
220VAC+10%; 50Hz+ 1Hz
24VDC+10%
Battery Operated
Integral Type
Remote Type
Explosion-proof, Integral
Flange connection (standard: ANSI, JIS, DIN, GB)
Thread connection (NPT, BSP, G)
Sanitary Tri-clamp connection
Code Nominal Diameter
(mm)
Flow Range
(m3/h)
Code Nominal Diameter (mm) Flow Range
(m3/h)

How to order

Model:□Pipe flange type;□Inserted type;□Integral type;□Remote type

Pipe DN       mm; pipe PN         MPa; Accuracy     %

Measuring Liquid:          □liquid;□gas;□saturated steam;□overheat steam;□mix steam

Measuring pipe material:□carton steel;□SS;□other:                       

Flow direct:□→;□←;□↑;□↓; other:

Installation Place:□Outdoor;□Indoor;□Other:

Fluid Viscosity:              Fluid(Gas)Relative humidity              %

Fluid density:Standard state            kg/m3,operating state           kg/m3

Flow rate:  □Max         m3/h,Min       m3/h,  Nor.        m3/h

          □Max        Nm3/h,Min      Nm3/h,  Nor.       Nm3/h

          □Max        kg/h,Min       kg/h,   Nor.        kg/h

 

Working pressure:□Max     MPa, Min     MPa, Nor.     MPa;

Pressure compensation: □Yes□No

Working temperature: □Max     , Min     , Nor.     ℃;

Temperature compensation: □Yes □No

Signal output:□Field indication; □4~20mA;□Pulse;□RS485;□0~10V;

Working condition:□Nor.;□vibration;□Damp;□flammable and combustible;□temperature  ℃

Fluid flow characteristics:□steady flow;□pulsating flow;□phase flow;□multiphase flow

Fluid state:□cleaning;□with trace gases;□with solid particle;□wet gas;□crystallizing;□dirty dirt

Special requirement:

Related Products