JC020 Integral Orifice Plate Flow Transmitter

JC020 Integral Orifice Plate Flow Transmitter is the high ratio of measuring range for differential pressure flow equipment, which is equipped by standard orifice plate and differential pressure transmitter (or temperature transmitter, pressure transmitter) and flow totalizer. It can measure the flow rate for gas, steam, liquid and natural gas.

JC020 Integral Orifice Plate Flow Transmitter

JC020 Integral Orifice Plate Flow Transmitter is the high ratio of measuring range for differential pressure flow equipment, which is equipped by standard orifice plate and differential pressure transmitter (or temperature transmitter , pressure transmitter) and flow totalizer . It can measure the flow rate for gas ,steam , liquid and natural gas.

Working Principle

When the fluid filled in the pipe is flowing through the throttling device in the pipe, the flow will shrink partly at the throttling device,  hence the flow velocity increases while the static pressure  decreases to form the differential pressure at the back and forth of the throttling device. The bigger the flow rate, the larger the differential pressure, so we can measure the flow according to differential pressure. This measuring method is based on Fluxion Continuity Equation (Mass Conservation Law)  and Bernoulli’s Principle (Energy Conservation Law). The differential pressure is related to flow, as well as other factors. For example, when the forms of throttling devices or physical properties (density, viscosity) of the fluids in the pipe are different, the differential pressure generates at the same flow rate is different.

orifice-plate-flow-transmitter-5.jpg

Technical Parameter for JC020 Integral Orifice Plate Flow Transmitter

Technical Parameter

1. Nominal Diameter: 15 mm ≤DN≤1200mm
2. Nominal Pressure: PN≤10MPa
3. Working temperature :-50℃≤t≤550℃
4.Turn-Down :1:10, 1:15
5. Accuracy :0.5%,1%

Characteristic

1.Easy structure , stable and long life , low cost
2. Orifice calculation is adopted international standard
3.Wide Application , full single-phase flow and part mixed-phase flow can be applied .

4.Standard orifice don’t need calibrate and can be applied

5.Completed integral orifice plate is easy for installation , it can directly Connect to differential pressure transmitter and pressure transmitter without pressure connecting pipe .

6. It can be used for high temperature more than 200 °C

7. High Stability is better than 0.1%FS/ year

8. High Static pressure :40MPa

9.don’t affect by temperature and static pressure ,Resistance to high over pressure

10.Continuous wokring 5 years without any calibration

Smart Model Characteristic 

1.Adopted imported monocrystal line silicon smart differential pressure transmitter

2.High accuracy , perfect self-diagnostic function
3.Its measuring range can be modified through programming

4.It can display cumulative flow rate , instant flow rate , pressure , temperature at the same time .

5.It can dynamically compensate the temperature and pressure online , can also diagnose and set the measuring range by itself.

6.Have various type communication interface
7.High stability
8.Wide Range ability >10:1

Model Selection for JC020 Integral Orifice Plate Flow Transmitter

Model Code Descriptions
JC020 Orifice plate and flange
Orifice Plate Type C Concentric sharp edge orifice plate
Nominal Pipe Size 015 Pipe diameter 15mm (1/2″)
020 Pipe diameter 20mm(3/4″)
025 Pipe diameter 25mm(1″)
040 Pipe diameter 40mm(1-1/2″)
050 Pipe diameter 50mm(2″)
065 Pipe diameter 65mm(2-1/2″)
080 Pipe diameter 80mm(3″)
100 Pipe diameter 100mm(4″)
125 Pipe diameter 125mm(5″)
:
900 Pipe diameter 900(35″)
1000 Pipe diameter 1000mm(40″)
Pressure Rating G 0.25-32Mpa
J JIS 10K RF/JIS 20kRF/JIS 30k RF
A ANSI 150 LB RF/300LB/600LB/900LB/1500LB
Plate Material P1 304SS
P2 316SS
O Others
Flange Material F1 C.S
F2 304SS
F3 316SS
N Without flange

How to order for JC020 Integral Orifice Plate Flow Transmitter

Throttle Device Parameters Table Project NO.
Table NO.
Page.     Total.
Data Calculation
Operation conditions Fluid name Throttle element type
Operating temperature ℃ Pressure taking type
Operating pressure  MPa Select scale
Flow Liquid       kg/h Max. Select differential pressure  kPa
Steam       kg/h Nor. Min. flow limit
Gas(standard)    Nm3/h Min. Reynolds number          Re

(normal flow)

Liquid           kg/m3 Area expansion correction

coefficient                   Fa

Steam           kg/m3 Expansion coefficient           ε
Gas (standard)    kg/m3 Flow coefficient               α
Uncertainty                  %
Permanent pressure loss        Pa
Diameter ratio                βt
Hole diameter of throttle      mm

element or segmental height

1/4 circle radius or

eccentricity degree            mm

Operating density          kg/m3 Throttle device standard
Dynamic viscosity         mPa.s
Kinematic viscosity        mm2/s Specification
Relative humidity (Φ)
Compression coefficient (Z) Model
Isentropic exponent  (cp/cv) Normal diameter (DN)
Allowable pressure loss        Pa Normal pressure (PN)           MPa
Pipe Nominal diameter (DN) Flange standard
Pipe instrument number Flange inner diameter         mm
Outside diameter/inner diameter  mm Structural length              mm
Material Pressure tape size             mm
Pressure tape location
material Throttle element
Flange
Bolt
Nut
Gasket
Remark