JCLC Oval Gear Flowmeter with LCD Display

JCLC Oval Gear Flowmeter is used for the continuous and intermittent measurement and control of the pipe liquid flow, which is typical of positive displacement meter, feature large flow range, low-pressure loss, large viscosity range, easy installation, high accuracy and can measure high temperature, high viscosity liquids with easy calibration.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months

JCLC Oval Gear Flowmeter

Oval gear meters are instruments used for the continuous and intermittent measurement and control of the pipe liquid flow, which is typical of positive displacement meter, feature large flow range, low-pressure loss, large viscosity range, easy installation, high accuracy and can measure high temperature, high viscosity liquids with easy calibration.

JC-LC oval gear meters are fitted with an on-site pointer indication and roller integration device which can indicate the liquid flow and intermittent flow passing through the pipeline. For the different liquids (acid, alkali, salt, organic solution, etc.), the meters can be made of different materials (cast iron, cast steel, stainless steel, etc.). The meters are widely used for flow measurement in the field of petroleum, chemical, chemical fiber, traffic, food industries and commerce, medical and sanitary departments.

Operation Principle

Oval gear meter is generally comprised of a flow transducer and a counter mechanism. The main part of the transducer is a measuring chamber which consists of a pair of oval wheels and a sealing coupling. The counter mechanism contains speed reduction gears, adjusting device, counter, and pulse transmitter, etc.

In the measuring chamber, a pair of oval wheels and cover plate make a crescent shape cavity which is used as a measuring unit. The oval wheels are rotated by the pressure difference in the inlet and outlet of the meter and drive the inlet liquid through the cavity to the outlet, each revolution of the oval wheels displaces fluid four times the volume of the cavity, the total revolutions of the oval wheels and the revolution rate will be transferred to the mechanical counter, and the total liquid volume and instantaneous flow will be known by the pointer display and the roller integration. The attached signal generator converts the rotary axial angular shift to the pulse signal and then transmits it to the electrical indicator for remote integrated flow and instantaneous flow indication and control.

positive-displacement-flowmeter-introduction

Technical Parameter for JCLC Oval Gear Flowmeter

1. Materials of main parts and the nominal operating pressure

Shell and cover cover plate oval wheel Rotary shaft Sheath of shaft Nominal pressureMPa
JCLC-A Cast steel Cast iron Stainless steel Bronze(with oil) or rolling bearing 1.6
JCLC-E Cast steel Cast iron、Stainless steel Under DN50 6.3

DN80-100  4.0

DN150-200  2.5

JCLC-Q Cast iron Cast iron Alloy aluminum, engineering material graphite 1.6
JCLC-B、C Stainless steel Stainless steel Stainless steel graphite 1.6、2.5
JCLC-L Cast

aluminum

Cast iron,

Stainless steel

Alloy

aluminum, engineering material

Bronze(with oil)、graphite、rolling bearing 1.6
Notes:1. 0Cr18Ni12Mo2Ti for type JCLC-C; 0Cr18Ni9Ti for type JCLC-B

2. Flange is convex under 2.5MPa ,and roughness at 6.3 MPa;and both of the above at 4.0 MPa。

2. Accuracy        class 0.5, class 0.2 (normal operating temperature -10℃~+60℃)

3. Measured media temp. (environment temperature -41℃~+50℃)

JCLC-A、B、C: -20℃~+60℃; 60℃~200℃(with high temp. radiator installed)

JCLC-Q、L: -20℃~+60℃;

4. Explosion-proof mark: ExiaⅡCT5, dⅡBT4

5. Flow range:                                                                  unit: m3/h

Type DN Viscosity (mPa. s)     
<0.3

<0.

0.3~0.8

0.

0.8~2 2~200 200~1000

 

1000~2000

 

 

 

 

 

JCLC-10 10 0.2-0.5 0.08-0.5

4

0.08-0.5 0.05-0.5 0.06-0.3 0.03-0.3 0.03-0.2
JCLC-15 15 0.75-1.

5

0.3-1.5 0.3-1.5 0.15-1.5 0.2-1.0 0.1-1.05 0.07-0.75
JCLC-20 20 1.5-3 1-3 0.4-3 0.5-3 0.3-3 0.4-2.1 0.2-2.1 0.15-1.5
JCLC-25 25 4-6 3-6 2-6 0.8-6 1-6 0.6-6 0.8-4.2 0.4-4.2 0.3-3
JCLC-40 40 9-15 7.5-15 5-15 2-15 2.5-15 1.5-15 2.1-10.5 1.0-10.5 0.7-7.5
JCLC-50 50 10-24 8-24 8-24 3-24 4.8-24 2.4-24 2.4-16.8 1.6-16.8 1.2-12
JCLC-B40、50 40、50 8-20 6-20 6-20 4-20 4-20 2-20 2.8-14 1.4-14 1.0-10
JCLC-B65 65 27-40 20-40 15-40 5-40 8-40 4-40 5.6-28 2.8-28 2-20
JCLC-80 80 40-60 30-60 20-60 8-60 12-60 6-60 8.4-42 4.2-42 3-30
JCLC-100 100 67-100 50-100 34-100 13.-100 20-100 10-100 14-70 6-70 5-50
JCLC-150 150 127-190 95-190 64-190 24-190 38-190 19-190 26.6-133 13.3-133 9.5-95
JCLC-200 200 227-340 170-340 114-340 43-340 56-340 34-340 47.6-238 23.8-238 17-170
Accuracy

class

0.5 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.5
Note 1.“gal/h” could be used for special orders.

2.Flow range of type JCLC-A80.2 is 1760gal/h~13200gal/h

Note: If the temperature of the metered liquid is higher than 80℃. the maximum flow rate will be 90% of the primary flow and the minimum will be 120%.

 

oval-gear-flowmeter-model-selection

How to order for JCLC Oval Gear Flowmeter

  1. Medium
  2. Pipe size
  3. Working pressure
  4. Working temperature
  5. Process connection
  6. Medium viscosity
  7. Flange standard

Application-oval-gear-flowmeter