Guided wave radar level meter are a kind of measuring instrument based on the time travel , radar wave are travelling as light speed, the travel time can be transformed into level signal by the electronic parts.
- Introduction
- Parameters
- Model
- How to Order
- Video
JC703 Coax Guided Wave Level Transmitter
Guided wave radar level meter are a kind of measuring instrument based on the time travel , radar wave are travelling as light speed , the travel time can be transformed into level signal by the electronic parts . The detector can send the HF pulse and spread along cable , when the pulse meet the level surface , it will be reflected and received by the receptor inside the instruments , then the receptor will transform the distance signal into level signal. This model is for liquid with small dielectric constant.
Features
1) For liquid with relatively lower electric constant , we can use the transmitter with twin rod probes to get good and precise measurement .
It is suitable for measurement of any liquid with dielectric constant no less than 1.6
2) Viscosity of the liquid should be no more than 500cst
3) Maximum measuring range of the transmitter with rod probe is 6 meters .
The measurement cannot be influenced with steam and foams .
Technical Parameter for JC703 Guided Wave Radar Level Transmitter
Working frequency : 100MHZ-1.8GHZ
Measuring range : cable type,0-30m;pole type,coaxial-type: 0-6m
Repeatability : ±3mm
Resolution: 1mm
Sampling : echo sampling 55 times/s
Response speed : >0.2S
Output current signal: 4 -20mA
Accuracy : <0.1%
Communication interface : HART communication protocol
Process connection: G1-1/2 Flange DN50,DN80,DN100,DN150
Process pressure : – 1-40bar
Power source : 24VDC(±10%), Ripple voltage:1Vpp
Power consumption: max 22.5mA
Environmental Condition: temperature -40℃~+80℃
Protection Class : IP68
Explosion-proof degree : EXiaIICT6
Two-wires connection cable: One two-core shield cable is used for instrument power supply and signal output
Electrical cable entry : two M20×1.5 or 1/2NPT (cable diameter 5–9mm)
Model Selection for JC703 Coax Guided Wave Level Transmitter
Explosion Proof Approval | |
P | Standard (without approval |
I | Intrinsically safe (Exia IICT6) |
C | Intrinsically safe (EXia IICT 6) |
G | Intrinsically safe+flameproof Approval (Exd ia II CT 6) |
Shape of Detecting /Material /Process temperature | |
A | Coax/Stainless steel 316L |
Process Connection /Material | |
GP | (F) Thread G11/2A |
NP | (G) Thread 11/2NPT |
FA | (L) Flange DN50/PTFE |
FX | Special design |
Seal/Process Temperature | |
A | Viton/(-30 to 150 ) °C |
B | Kalrez(-40 t0 150)°C |
Electronic | |
B | (4-20)mA/Hart 2 wire |
C | (4-20)mA(22.8-26.4)V DC /Hart 2 wire/4 wire |
D | (198-242) VAC/Hart 4 wire |
Housing /Protection | |
A | Aluminium/IP67 |
B | Plastic/IP66 |
D | Aluminium (2 chamber)/IP67 |
G | Stainless steel 316L/IP 67 |
Cable Entry | |
M | M20*1.5 |
N | 1/2”NPT |
Display /Programming | |
A | Yes |
X | NO |
How to order for JC703 Coax Guided Wave Level Transmitter