JC090 Compact Type Pipe Electromagnetic Flowmeter

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months

Electromagnetic Flowmeter Calibration

  • Twice calibration within 24 hours
  • Two automation calibration system
  •  Standard meter with 0.025% accuracy
  • Tracking Calibration Report
  • Min size 6mm to max size 2600mm
  • Standard Accuracy 1%, best accuracy 0.5%
Electromagnetic flowmeter calibration by Instruthink
  • Electromagnetic flowmeter -introduction

Electromagnetic Flowmeter Feature

  • Simple structures, firm, no movable parts, and long operation life
  • No intercepting fluid parts, no pressure loss, and fluid clogging
  • No mechanical inertia, quick response, and good stability apply in the automatic examination, adjustment, and control
  • Measuring accuracy is not influenced by physical parameters such as style, temperature, viscosity, density, and pressure.
  • Employ Teflon or rubber liner and different combinations of an electrode material such as Hastelloy C, Hastelloy B, 316L,
  • Titanium and adapt to the need of different mediums.
  • Supply many styles of flowmeters such as inline type and insertion type, etc.
  • Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.
  • Integral type flowmeters and remote type flowmeters.
  • LCD backlight display with high clearness

JC090 Compact Type Pipe Electromagnetic Flowmeter

Introduction

An electromagnetic flowmeter is a kind of inductional instrument designed by Faraday’s law of electromagnetic induction to measure the flow of conductive media in the tube. It adopts the technology of insertion of a single chip to realize digital excitation and employs CAN local Fieldbus.

The electromagnetic flowmeter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Electromagnetic flow meters are widely used in industrial sectors such as the chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply, and removal, etc.

Besides measuring the flow of general conductive liquid electromagnetic flowmeter can measure the flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid, and strong alkali.

Smart electromagnetic flow meters consist of sensors and smart signal transducers. And it can be classified into two structures— integral type and remote type according to the set-up form of the sensor and transducer. In terms of integral type electromagnetic flow meters, transducer and sensor directly assemble as a whole and can not be dissociated. It is usually used at the scene where the environmental situation is good. To remote type electromagnetic flow meters transducer composes a product through a special electric cable and sensor. The sensor is installed at the scene and the transducer is installed in the place where the conditions are good. It is usually used at the scene where the environmental situation is poor, such as underground wells, high temperature, and the place where people can not reach.

Technical Parameter

Suitable Diameter DN10~DN2600 (below DN25 non-standard, which should be customized)
Electrodes Materials 316L (stainless steel), Hastelloy C, Hastelloy B, Titanium, Tantalum
Suitable Fluid Liquid with a conductive ratio of more than 5 μs/cm
Measuring Range 0.1~10m/s (extendable to 15m/s)
Upper Limit of Span 0.5~10m/s. 1~5m/s recommended
Accuracy 0.3%, 0.5%,1.0%
Output Signals 4~20mADC, load<= 750ohm, 0~3kHz, 5V with source and changeable width.

high terminal and effective frequency output , RS485 interface

Operation Pressure 1.0MPa, 1.6MPa, 4.0MPa, 16MPa (special)
Fluid Temperature -20C~80C, 80C~130C,130C~180C Depending on Lining Material
Ambient Temperature Sensor -40C~80C. transducer -15C~50C
Ambient Humidity <= 85%RH (at 20C)
Cable Outlet Size M20(16) ×1.5,1/2”NPT
Power Supply 220VAC±10%, 50Hz±1Hz, 24VDC±10%
Power Consumption <=8W
Protection Ratings Integral type: IP65. remote type: sensor IP68, transducer IP65
Materials of Liner PTFE, soft rubber, hard rubber, PFA, etc
Process Connection Flange: ANSI, DIN, JIS, ISO, GB standard

Thread :NPT ,BSP ,G

Tri-clamp connection

Earthing Materials 316L (stainless steel), HC, Ti, Ta, Cu
Housing Material Carbon steel, 304SS, 316SS

Model Selection

Code Nominal Diameter

(mm)

Flow Range

(m3/h)

Code Nominal Diameter (mm) Flow Range

(m3/h)

JC-090-10

JC-090-15

JC-090-20

JC-090-25

JC-090-32

JC-090-40

JC-090-50

JC-090-65  JC-090-80

JC-090-100

JC-090-125

JC-090-150

JC-090-200

JC-090-250

JC-090-300

JC-090-350

JC-090-400

Dn10

DN15

DN20

DN25

DN32

DN40

DN50

DN65

DN80

DN100

DN125

DN150

DN200

DN250

DN300

DN350

DN400

0.085-2.8

0.19~6.36

0.34~11.3

0.53~17.66

0.87~28.94

1.36~45.22

2.12~70.65

3.58~119.40

5.43~180.86

8.48~282.6

13.25~441.56

19.08~635.85

33.91~1130.40

52.99~1766.25

76.30~2543.40

103.86~3461.85

135.65~4521.60

JC-090-450

JC-090-500

JC-090-600

JC-090-700

JC-090-800

JC-090-900

JC-090-1000

JC-090-1200

JC-090-1400

JC-090-1600

JC-090-1800

JC-090-2000

JC-090-2200

JC-090-2400

JC-090-2600

DN-450

DN-500

DN-600

DN-700

DN-800

DN-900

DN-1000

DN-1200

DN-1400

DN-1600

DN-1800

DN-2000

DN-2200

DN-2400

DN-2600

171.00~5722.65

211.95~7065.00

305.21~10173.00

415.42~13847.40

542.59~18086.40

686.72~22890.60

847.80~28260.00

1220.83~40694.40

1661.69~55389.60

2170.37~72345.60

2746.87.00~91562.40

3391.20~113040.00

4103.35~136778.40

4883.33~162777.60

5731.13~191037.60

Code Electrode Material
K1

K2

K3

K4

K5

K6

K7

SS 316L

Hastelloy B

Hastelloy C

Titanium

Tantalum

Pt/Iridium Alloy

Stainless Steel Painting Tungsten Carbide

Code Material of liner
C1

C2

C3

C4

C5

C6

C7

PTFE (F4 or Teflon)

Fluorinated Ethylene Propylene (FEP)

Fs

PO (Soft Rubber)

Polyurethane Rubber (PUR)

Hard Rubber

PFA

Code Function
E1

E2

E3

F1

F2

F3

F4

T1

T2

T3

P1

P2

P3

P4

P0

D1

D2

D3

J1

J2

J3

W1

W2

W3

Class 0.3%

Class 0.5%

Class 1.0%

4~20mADC, load ≤750Ω

0~3kHz, 5V active, changeable pulse, high-terminal and effective frequency output

RS 485 interface (Modbus)

HART

Normal Temperature

High Temperature

Ultra Temperature

1.0MPa

1.6MPa

4.0MPa

16MPa

Special Pressure

220VAC+10%; 50Hz+ 1Hz

24VDC+10%

Battery Operated

Integral Type

Remote Type

Explosion-proof, Integral

Flange connection (standard :ANSI,JIS ,DIN,GB)

Thread connection (NPT ,BSP ,G)

Sanitary Tri-clamp connection

Related Inserted Electromagnetic Flowmeter

Instruthinksupply a complete solution for electromagnetic flowmeter, not only compact type electromagnetic flowmeter, but also inserted electromagnetic flowmeter.

Send Your Inquiry Now